Please use this identifier to cite or link to this item: https://dipositint.ub.edu/dspace/handle/2445/208368
Title: Ambulatory MiniArc Precise sling under local anesthesia for stress urinary incontinence: Feasibility and outcome
Author: Campos Delgado, Míriam
Quetglas-Muñoz, Cecilia
Barahona Orpinell, Marc
García-Tejedor, Amparo
Ponce i Sebastià, Jordi
Keywords: Cirurgia ambulatòria
Anestèsia local
Incontinència urinària
Ambulatory surgery
Local anesthesia
Urinary incontinence
Issue Date: Aug-2019
Abstract: Aims: The aim of the study is to assess the feasibility of ambulatory stress urinary incontinence (SUI) surgery using the MiniArc Precise single-incision urethral sling without increasing the number of complications. Settings and design: This was a retrospective observational study of prospectively collected data carried out in a Tertiary Referral Hospital in Barcelona, Spain. Materials and methods: Forty patients diagnosed with SUI or stress predominant mixed urinary incontinence (MUI) treated surgically between November 2011 and November 2013. The MiniArc Precise® sling was inserted under local anesthesia in the ambulatory setting. Satitistical analysis used: Descriptive statistics included frequencies and percentages for categorical variables and mean and range for quantitative variables. The statistical package used was SPSS version 17.0. Results: Urodynamic studies showed SUI in 78% of cases and stress predominant MUI in 17%. Clinical findings included SUI in 56% of cases and MUI in 44%, with positive stress tests in all participants. The mean intraoperative pain (1-10 Visual Analog Scale) was 2. All patients were satisfied with the use of local anesthesia in the outpatient setting. Perioperative complications did not occur. One case of urinary retention and two cases of urinary tract infection (UTI) developed within this 1st month after operation and were successfully managed conservatively. Midterm complications included eight cases of UTI and four de novo urge incontinence. Conclusions: Placement of the MiniArc Precise sling under local anesthesia is a feasible and safe technique, which when carried out by an experienced surgeon allows to be done as an outpatient basis without increasing the rate of postprocedural complications. Keywords: Ambulatory surgical procedures, local anesthesia, MiniArc Precise, patient satisfaction, stress urinary incontinence, suburethral slings
Note: Reproducció del document publicat a: https://doi.org/10.4103/GMIT
It is part of: 2019, vol. 8, num.3, p. 113-117
URI: https://hdl.handle.net/2445/208368
Related resource: https://doi.org/10.4103/GMIT
ISSN: 2213-3089
Appears in Collections:Articles publicats en revistes (Ciències Clíniques)

Files in This Item:
File Description SizeFormat 
219139.pdf320.9 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons